2.3

Removal of PCB

Procedure
Step
1. Removing the controller
PCB
1
Remove 1 screw of the
PCB, and release two
tabs.
2
Release the tabs of the
terminal board, and
open the terminal
board.
3
Disconnect each
connector on the back
of the terminal board.
4
Disconnect the service
monitor PCB connector.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Base bar
Tab
Outdoor Unit (50 / 52 / 58 / 68 / 75 Class)
Points
Tab
" Release the tab to remove
the service monitor PCB.