DAIKIN ROOM AIR CONDITIONER

Operation Manual

MODELS
FDXS25CVMB
FDXS35CVMB
CDXS50CVMB CDKS50CVMB
CDXS60CVMB CDKS60CVMB
FDKS25CVMB
FDKS35CVMB
English
Deutsch
Français
Nederlands
Español
Italiano
ΕλληνικÜ
Portugues
Рóссêий

Advertisement

Table of Contents
loading

Summary of Contents for Daikin Inverter FDXS25CVMB

  • Page 1: Operation Manual

    DAIKIN ROOM AIR CONDITIONER MODELS FDXS25CVMB FDKS25CVMB Operation Manual FDXS35CVMB FDKS35CVMB CDXS50CVMB CDKS50CVMB CDXS60CVMB CDKS60CVMB English Deutsch Français Nederlands Español Italiano ΕλληνικÜ Portugues Рóссêий...
  • Page 2: Table Of Contents

    CONTENTS READ BEFORE OPERATION Safety precautions ......... 2 Names of parts..........4 Preparation Before Operation ......7 OPERATION AUTO · DRY · COOL · HEAT · FAN Operation ............. 10 POWERFUL Operation ........ 12 OUTDOOR UNIT SILENT Operation ..13 HOME LEAVE Operation ......
  • Page 3: Safety Precautions

    • Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself. Incorrect work will cause electric shocks, fire etc. For repairs and reinstallation, consult your Daikin dealer for advice and information. • The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for some reason any refrigerant happens to leak into the room, make sure it does not come in contact with any flame as of gas heaters, kerosene heaters or gas range.
  • Page 4: Installation Site

    • Do not stand or sit on the outdoor unit. Do not place any object on the unit to avoid injury, do not remove the fan guard. • Do not place anything under the indoor or outdoor unit that must be kept away from moisture. In certain conditions, moisture in the air may condense and drip.
  • Page 5: Names Of Parts

    Names of parts I Indoor Unit...
  • Page 6: I Outdoor Unit

    I Outdoor Unit I I I I Indoor Unit 1. Air outlet 10. Indoor Unit ON/OFF switch: • Push this switch once to start operation. 2. Air outlet grille: (Field supply) Push once again to stop it. • Appearance of the Air outlet grille and Air inlet •...
  • Page 7: Remote Controller

    I Remote Controller HOME LEAVE ON/OFF TEMP POWERFUL MODE SILENT CANCEL TIMER < > ARC433A7, A8 1. Signal transmitter: 7. MODE selector button: • It sends signals to the indoor unit. • It selects the operation mode. (AUTO/DRY/COOL/HEAT/FAN) (page 10.) 2.
  • Page 8: Preparation Before Operation

    Preparation Before Operation I To set the batteries Position + and – correctly! 1. Press with a finger and slide the front cover to take it off. 2. Set two dry batteries (AAA). 3. Set the front cover as before. ATTENTION I I I I About batteries •...
  • Page 9: Operation

    Preparation Before Operation I To operate the remote controller • To use the remote controller, aim the transmitter at the indoor unit. If there is anything to block signals between the unit and the remote control- ler, such as a curtain, the unit will not operate. •...
  • Page 10: Operation

    I To set the clock 1. Press “CLOCK button”. is displayed. blinks. 2. Press “TIMER setting button” to set the clock to the present time. HOME LEAVE ON/OFF Holding down “ ” or “ ” button rapidly TEMP POWERFUL increases or decreases the time display. 3.
  • Page 11: Auto · Dry · Cool · Heat · Fan Operation

    OPERATION AUTO · DRY · COOL · HEAT · FAN Operation The air conditioner operates with the operation mode of your choice. From the next time on, the air conditioner will operate with the same operation mode. I To start operation 1.
  • Page 12: To Change Airflow Rate Setting

    I To change the air flow rate setting 5. Press “FAN setting button”. DRY mode AUTO or COOL or HEAT or FAN mode Five levels of air flow rate setting from “ ” to “ ” plus “ ” “ ”...
  • Page 13: Powerful Operation

    POWERFUL Operation POWERFUL operation quickly maximizes the cooling (heating) effect in any operation mode. You can get the maximum capacity . I To start POWERFUL operation 1. Press “POWERFUL button”. • POWERFUL operation ends in 20 minutes. Then the system automatically operates again with the settings which were used HOME LEAVE ON/OFF...
  • Page 14: Outdoor Unit Silent Operation

    OUTDOOR UNIT SILENT Operation OUTDOOR UNIT SILENT operation lowers the noise level of the outdoor unit by changing the frequency and fan speed on the outdoor unit. This function is conve- nient during night. I To start OUTDOOR UNIT SILENT operation 1.
  • Page 15: Home Leave Operation

    HOME LEAVE Operation HOME LEAVE operation is a function which allows you to record your preferred temperature and air flow rate settings. I To start HOME LEAVE operation 1. Press “HOME LEAVE button”. • “ ” is displayed on the LCD. •...
  • Page 16 I What’s the HOME LEAVE operation? Is there a set temperature and air flow rate which is most comfortable, a set temperature and air flow rate which you use the most? HOME LEAVE operation is a function that allows you to record your favor- ite set temperature and air flow rate.
  • Page 17: Timer Operation

    TIMER Operation Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use OFF TIMER and ON TIMER in combination. I To use OFF TIMER operation • Check that the clock is correct. If not, set the clock to the present time.
  • Page 18: To Combine On/Off Timers

    I To use ON TIMER operation • Check that the clock is correct. If not, set the clock to the present time (page 9.). 1. Press “ON TIMER button”. is displayed. blinks. 2. Press “TIMER Setting button” until the time setting reaches the point you like.
  • Page 19: Note For Multi System

    Note for Multi System 〈〈 〈〈 〈〈 〈〈 〉〉 〉〉 〉〉 〉〉 What is a “Multi System”? This system has one outdoor unit connected to multiple indoor units. Functions depend on the model. See the list of functions and appli- room cable models (*2) on the next page.
  • Page 20 I Maximum Power Input Limitation • The Maximum Power Input Limitation needs to be set when the unit is installed. Contact DAIKIN dealer. • This function limits the power input of the unit to 1700W. It is recommended for locations with low-capacity circuit breakers.
  • Page 21: Care And Cleaning

    CARE Care and Cleaning • Only a qualified service person is allowed to CAUTION perform maintenance. • Before cleaning, be sure to stop the operation and turn the breaker OFF. I Cleaning the air filter 1.Removing the air filter. • Rear suction Pull the bottom side of the air filter backwards, over the 3 bends.
  • Page 22 • Clean the drain pan periodically, or drain piping may be clogged with dust and may result in water leakage. Ask your DAIKIN dealer to clean them. • Prepare a cover locally to prevent any dust in the air around the indoor unit from getting in the drain pan, if there is a great deal of dust present.
  • Page 23: Trouble Shooting

    Trouble Shooting These cases are not troubles. The following cases are not air conditioner troubles but have some reasons. You may just continue using it. Case Explanation Operation does not start soon. • This is to protect the air conditioner. •...
  • Page 24: Check Again

    Check again. Please check again before calling a repair person. Case Check The air conditioner does not • Hasn’t a breaker turned OFF or a fuse blown? operate. • Isn’t it a power failure? (OPERATION lamp is off.) • Are batteries set in the remote controller? •...
  • Page 25: Call The Service Shop Immediately

    Call the service shop immediately. WARNING I I I I When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker OFF. Continued operation in an abnormal condition may result in troubles, electric shocks or fire. Consult the service shop where you bought the air conditioner.
  • Page 26: Fault Diagnosis

    Fault diagnosis. FAULT DIAGNOSIS BY REMOTE CONTROLLER In the ARC433A series, the temperature display sections on the main unit indicate corresponding codes. 1. When the TIMER CANCEL button is held down for 5 seconds, a “ ” indication flashes on the temperature display section.
  • Page 27 LED ON OUTDOOR UNIT PCB 3MXS, 3MKS, 4MXS, 4MKS series GREEN MICROCOMPUTER MALFUNCTION NORMAL DETECTION DIAGNOSIS LED-A LED1 LED2 LED3 LED4 NORMAL CHECK INDOOR UNIT HIGH PRESSURE PROTECTOR WORKED OR FREEZE-UP IN OPERATING UNIT OR STAND-BY UNIT ∗ OVERLOAD RELAY WORKED OR HIGH DISCHARGE PIPE TEMPERATURE FAULTY COMPRESSOR START INPUT OVERCURRENT ∗...
  • Page 28 3P131999-2E M04B107A (0507) HT...