Night Set Mode - Daikin Super Multi NX C-Series Service Manual

Super multi nx c-series
Table of Contents

Advertisement

Main Functions
1.6

Night Set Mode

When the OFF timer is set, the Night Set circuit automatically activates.
The Night Set circuit maintains the airflow setting made by users.
The Night Set
The Night Set circuit continues heating or cooling the room at the set temperature for the first
Circuit
one hour, then automatically lowers the temperature setting slightly in the case of cooling, or
raises it slightly in the case of heating, for economical operations. This prevents excessive
heating in winter and excessive cooling in summer to ensure comfortable sleeping conditions,
and also conserves electricity.
Cooling Operation
Heating Operation
76
0.5°C
1 hour
30 minutes
+0.5°C
Timer operation
temperature shift
Night Set Circuit ON
When outside temperature is normal and
room temperature is at set temperature
When outside temperature is high (27°C or higher).
Thermostat
setting
Timer operation
Night Set Circuit ON
Temperature
setting +1°C
0.5°C
Temperature
setting +0.5°C
Temperature
setting
Operation stops
at the set hours
+0.5°C temperature shift
Temperature setting remains the same
2°C
1 hour later
SiE12-411