P.E. Beams
Step 20 - Fitting the P.E. Beams (optional)
a.
Affi x the P.E. Beams in a strategic location within
the doorway. We recommend 150mm above the
fl oor level and as close as possible to the door
opening, inside the garage.
b.
Connect the wires from the P.E.Beams wiring
harness to terminal block (Fig. 46). The wiring
diagram is for Model PE-2 (Order Code 90214).
c.
Make sure that you are using the correct resistor
i.e. 2k2 ohms (Red Red Red gold) and connecting
to number 2 (two) and 4 (four) terminal on the PE-2
receiver. Make sure to align the beams correctly.
Follow the manual supplied with the P.E. Beams.
WARNING: When using P.E. Beams, the doorway
must be clear of all obstructions and persons at all
times. The location of the beams and manner in
which it is installed might not give safety protection
at all times. Check to make sure that the height of
the beam and type used give maximum protection
possible.
WARNING: Install the P.E.Beams as per diagram in
(Fig. 46). Tampering with P.E.Beams could result
in serious personal injury and/or property damage
and will void the warranty.
Step 21 - key switch connection
Gdo-11v1 Has The Input To Connect Bell Switch
Or Key Switch To Open Or Close The Door.
Connect The Key/bell Switch As Per Diagram (Fig.
47).
Step 22 - Auxiliary out put
The auxiliary output can be used to control alarm or
another garage door opener. A valid transmission
from the pre-coded transmitter will cause the
auxiliary out put to pulse for approximately 1
(one) second. The maximum DC voltage must not
exceed 35 volts DC. Maximum current must not
exceed 80 ma.(Fig. 48).
Receiver
Model PE-2
RESISTOR = 2K2
0.25 WATT
+
-
BLACK
BLACK
BLACK
YELLOW
RED
RED
YELLOW
External
device
Alarm, Door
opener etc.
GDO-11v1 SecuraLift ®
Owner Installation Instructions
Transmitter
+ -
fi g
46
BLACK
RED
fi g
47
30V PWR
PE
PE (0V)
GND
OSC
AUX OUT
PWR
PE
PE ( 0V )
fi g
48
GND
OSC
AUX OUT
25
Need help?
Do you have a question about the GDO-11v1 SecuraLift and is the answer not in the manual?
Questions and answers
garage door motor running but wont open or shut after I manually opened during a power black out
My securalift GDO-11v1 door is not working. I manually opened during a power outage. Now I can hear it running but door not moving. Have re engaged the door with the cord
The Automatic Technology GDO-11v1 SecuraLift garage door motor may still be running but not opening or shutting after manual operation during a power blackout due to a residual charge in the batteries. This can cause the opener to become active even when the main power is off.
This answer is automatically generated