Mounting an external power supply in a rack

DANGER
Make sure the rack or cabinet housing the device is adequately secured to prevent it from
becoming unstable or falling over.
Complete the following steps to install an external power supply in a rack.
1.
Remove the rack mount kit from the shipping carton. The kit contains two L-shaped mounting
brackets, six sink-head mounting screws, four rack-mounting screws, and four cage nuts.
2.
Using a Phillips screwdriver, attach the mounting brackets to the sides of the external power supply
using six sink-head screws.
FIGURE 44 Attaching the mounting brackets for the ICX 6400–EPS1500
3.
Mount the external power supply in a rack using four rack-mounting screws.
4.
Use the four cage nuts to screw the device to the rack mount holes.
Brocade ICX 6430 and ICX 6450 Stackable Switches Hardware Installation Guide