ICX 6450 stacking ports and trunks

FIGURE 31 SFP+ ports on the front panel of the 24-port model of an ICX 6610 device
1.
2.
FIGURE 32 SFP+ ports on the front panel of the 48-port model of an ICX 6610 device
1.
2.
ICX 6450 stacking ports and trunks
The ICX 6450 contains four SFP+ ports in slot 2 on the front panel that can be used as uplink (data)
ports or as stacking ports. The figure below shows the ports in slot 2; the top row consists of ports 1
and 3, and the bottom row consists of ports 2 and 4.
FIGURE 33 Stacking ports on the front panel of an ICX 6450 device
1.
2.
3.
4.
Ports 1 and 3 are default stacking ports. Default stacking ports have the capability to accept special
stacking packets during a CLI-initiated command sequence of the Secure Setup utility. If ports 1 and 3
are not used as stacking ports, you can use them as data ports. Configuration is not required to use
them as data ports.
38
Two trunk connections to ICX 6450 peripheral devices (four ports total).
Two single (untrunked) port connections to ICX 6450 peripheral devices.
Slot 3: 10 Gbps SFP+ ports 1-8
Slot 1: 10/100/1000 Mbps ports
Slot 3: 10 Gbps SFP+ ports 1-8
Slot 1: 10/100/1000 Mbps ports
Console port
Slot 2 (SFP and SFP + uplink or stacking ports)
Out-of-band management port
Slot 1 (10/100/1000 Mbps ports)
Brocade ICX 6430 and ICX 6450 Stackable Switches Hardware Installation Guide