Custom V/F Pattern; Setting Operation Conditions; Reverse Run Prohibit (N006); Multi-Step Speed Selection - Saftronics FP5/GP5 Series Technical Manual

Table of Contents

Advertisement

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor
Chapter 6: Programming Features
6.2.2.

Custom V/f Pattern

Set each pattern when using a special motor (high-speed motor, etc.) or when requiring special torque adjustment of
machine.
Make sure to satisfy the following
conditions for setting of constants
n012 to n018.
n017 < n015 < n014 < n012
Constant No.
n012
n013
n014
n015
n016
n017
n018
∗ For 400 V class, the value is twice that of 200 V class.
Increasing the voltage of the V/f pattern increases motor torque, but an excessive increase may cause the following:
Inverter malfunction because of motor overexcitation.
Motor overheat or excessive vibration.
Increase voltage gradually while verifying the motor current.
6.3

Setting Operation Conditions

6.3.1.

Reverse Run Prohibit (n006)

"Reverse run disabled" setting does not accept a reverse RUN command from the control circuit terminal or Digital
Operator. This setting is used for applications where a reverse RUN command can cause problems.
Setting
6.3.2.
Multi-Step Selection
By combining frequency reference and input terminal function selections, up to four steps of speed can be set.
Four step speed change
n002
=
n025
=
n026
=
n027
=
n028
=
n038
=
n039
=
Firmware – S2011 and S3012
Revision: 1 (9/98)
Name
Maximum output frequency
Maximum voltage
Maximum voltage output
frequency (base frequency)
Middle output frequency
Middle output frequency
voltage
Minimum output frequency
Minimum output frequency
voltage
Description
0
Reverse run enabled
1
Reverse run disabled
1 (Operation mode selection)
30.0 Hz
40.0 Hz
50.0 Hz
60.0 Hz
9 (Multi-function contact input Terminal S5)
10 (Multi-function contact input Terminal S6)
Figure 18
Custom V/f Pattern Setting
Unit
Setting Range
50.0 − 400.0 Hz
0.1 Hz
0.1 − 255.0 V
0.1 V
0.2 − 400.0 Hz
0.1 Hz
0.1 −399.9 Hz
0.1 Hz
0.1 − 255.0 V
0.1 V
0.1 − 10.0 Hz
0.1 Hz
0.1 − 50.0 V
0.1 V
38
Factory Setting
60.0 Hz
[
[
200.0 V
60.0 Hz
3.0 Hz
[
[
15.0 V
1.5 Hz
[
[
10.0 V
© Saftronics, Inc.

Hide quick links:

Advertisement

Table of Contents
loading