Cabinet Alarm - LG iPECS Feature Description & Operation

Telephone network
Table of Contents

Advertisement

IPECS
Release 5
Feature Description & Operation
6.6 C
A
ABINET
LARM
Description
The Cabinet Alarm alerts the Attendant of a fault in the fans or power supplies in a cabinet. The
alarm notification displays the cabinet number. The cause of the fault, cabinet fan, PSU or PSU
fan is shown on the Cabinet Attributes Web Admin page (
at the Attendant's phone by dialing the Alarm Stop code or, if assigned, pressing the {
button.
Operation
When an alarm condition occurs, the Attendant phone will display:
CABINET XXX STS FAULT
System Attendant
To assign a Flex button as an {
[
] + {
PGM
FLEX
To terminate an Alarm Signal while idle:
1. Dial the Alarm Stop code, 565, confirmation tone is received and the display returns to
normal.
Or,
1. Press the {
ALARM STOP
Conditions
1. The PSU serial port must be connected to the gateway Module or MFIM identified in the
Cabinet Attributes Web Admin page (PGM 197).
2. If the PSU is connected to a WTIM, refer to the Description and Installation Manual for proper
DIP-switch settings; DIP-switch 3 must be set to the Off position.
3. The notification identifies the cause of the alarm as FAN1 or FAN2 for the Main cabinet fans,
PSU1 or PSU2 for a power supply fault or PSU1 FAN or PSU2 FAN.
Programming
S
YSTEM
Related features
Alarm Signal/Door Bell
Emergency Call Attendant Alert
Hardware
ALARM STOP
} + '565' + [
]
SAVE
} button.
1. Cabinet Attribute (PGM 197)
197). The alert may be terminated
PGM
} button to terminate the Alarm Signal:
6-7
5.0
}
ALARM STOP