5.1.4 OUTPUT CHECK (SP5-804)
CAUTION: To avoid mechanical or electrical damage, do not leave electrical
components on continuously for a prolonged period of time.
1. Access SP5-804.
2. Select the number that corresponds to the component you wish to check (see
the table below), then press OK or '.
3. Press "1", then press OK or the ' key to check that component.
4. To interrupt the test, re-enter SP 5-804 and enter a value of "0".
Input Check Table
Number
1
Polygon mirror motor (400 x 400 dpi)
2
Polygon mirror motor (600 x 600 dpi)
3
Main motor
4
Fan motor (slow)
5
Fan motor (fast)
SM
Output Check
Code:
0
Data:
Description
5-25
USING SERVICE PROGRAM MODE
0
B046M011.WMF
B044/B045/B046