Rack Mounting the Chassis

Danger:
• Only trained and qualified personnel should install or replace this equipment.
Caution:
• There are no handles or hand grips on the 7450 ESS-1. Lift the router from underneath. Do
• When rack mounting the chassis in an equipment rack, do not stack other ESS-1 units or
The 7450 ESS-1 router chassis is designed for front and middle-mount installation into a 19-inch
rack. The rack mounting hardware (including rack bolts) is factory installed to front-mount the
chassis in a 19-inch rack.
It is easier to install the ESS-1 chassis in the rack with two people, one person to hold the router
and one person to secure it into the rack.
Required tools:
Before you begin, verify:
7450 ESS-1
not lift the router by the MDA slots.
any other equipment directly on top (where the bottom unit is supporting other devices).
Each unit must be secured into the rack with the appropriate mounting apparatus.
Use a screwdriver to loosen and tighten the mounting bracket bolts.
The equipment rack is securely installed, anchored, and grounded. Refer to the rack
manufacturer's documentation for instructions.
The power to the rack is OFF.
Installing the 7450 ESS-1