Rack-Mounting

Rack-Mounting
Refer to the following important guidelines before installing the chassis in a rack:
Two people are required to rack mount the switch: One person to lift the chassis into position and one
person to secure the chassis to the rack using the rack mount screws.
The chassis has rack-mount flanges that support standard 19-inch rack mount installations.
Alcatel-Lucent Enterprise does not provide rack-mount screws. Use the screws supplied by the
rack vendor.
To prevent a rack from becoming top heavy, it is recommended that you install the switch at the bottom
of the rack whenever possible.
Note. If you are installing the switch in a relay rack, be sure to install and secure the rack per rack manu-
facturer's specifications.

Installing Rack Mount Flanges

To install rack mount flanges, start by making sure the spring clip is in the out (disengaged) position.
1
Insert the tab into the chassis slot as shown.
2
page 3-40
Tab
Slot
OmniSwitch 6860 Hardware Users Guide
Chassis and Power Supplies
Clip in "Out"
(disengaged)
position
October 2022