Configuring Slot, Iom, And Mda Parameters; Card And Card-Type Commands - Alcatel-Lucent 7450 ESS-1 Installation Manual

Ethernet service switch
Hide thumbs Also See for 7450 ESS-1:
Table of Contents

Advertisement

Configuring Slot, IOM, and MDA Parameters

Configuring Slot, IOM, and MDA Parameters

After the 7450 ESS-1 is initialized, the MDA and port parameters can be configured. Even though
the IOM is an integral part of the unit, the slot and card type must be manually specified. The
MDA slot and MDA type must be configured in order to configure ports. Ports cannot be
configured until the MDA is configured.
Configure components in the following order:

Card and Card-Type Commands

NOTE: When configuring the chassis slot (Step 1), the slot number value is always 1 for ESS-1
models.
In the
provision the chassis slot and IOM:
Step 1
Step 2
Step 3
Page 72
1. Card slot number
2. Card type
3. MDA slot number
4. MDA type
5. Ports
context, use the following CLI commands and syntax examples to
config>card
Command
card
slot-number
card-type card-type
no shutdown
Example
card 1
card-type iom-20g
no shutdown
7450 ESS-1