Free-Arm Adapter Sensor - Fritz Gegauf Bernina artista 630 Service Manual

Table of Contents

Advertisement

What to test:
Technical information data entry.
Technical data can be entered here in this page, using the virtual
keyboard.
The entered data give the technician information on already made
improvements.
Use the right scrolling arrow
What to test:
Total hours and stitch count in EMB
Time Power: On,
Time Standby,
Time Embroidery,
6b Free-arm adapter sensor:
What to test:
Attach free-arm adapter and embroidery module.
Press icon b. The bar appears in green after recognition of the sensor.
Test Successful! appears.
Test failed! appears if an error occurred.
Repairing note:
Ensure that the free-arm adapter and EMB are in the correct positions.
Check connecting cables. Replace if necessary.
Check EMB PCB and S-Print. Replace if necessary.
Replace sensor.
to go to the total hours and stitch count information.
= Total hours under power
= Total hours under power but without activity
= Stitching time in embroidery mode
Service-Manual_artista_630_640_english_V4.01_032069_50_04.doc