6-3 Extended Menu
Menu items in the 600s, relating to the time code generator (continued)
Item number
Item name
609
TCG CF FLAG
610
REGEN CONTROL
MODE
6-24
Setup Menu
Settings
Select whether or not the color framing flag is set in
the blank bit of the timecode.
OFF : Color framing flag is not set.
ON: Color framing flag is set.
AUTO: Color framing flag is set or not depending
upon the color framing phase relationship between
the recorded video signal and the timecode.
When AUTO is selected, color framing is controlled
as follows according to the operating mode of the
timecode generator.
In INT PRESET mode (the INT/EXT switch is set
to INT, the PRESET/REGEN switch is set to
PRESET, and in modes other than the automatic
editing mode): the timecode is generated with
color framing locked to the video signal, and the
color framing flag is set.
In INT REGEN mode (the INT/EXT switch is set
to INT, the PRESET/REGEN switch is set to
REGEN, and in the automatic editing mode), and
also in EXT mode (the INT/EXT switch is set to
EXT): the timecode is generated with color
framing locked to the video signal, and the color
framing flag is not set.
When editing with two DNW-A25WS/A25WSP
units, if you use the control panel for editing
operation, select whether or not the timecode is
automatically regenerated.
AS&IN : In editing with this unit as the recorder,
regardless of the setting of the INT/EXT and
PRESET/REGEN switches, in assemble and insert
editing , the timecode generator regenerates
according to the timecode on the tape.
ASSEM: In editing with this unit as the recorder,
regardless of the setting of the INT/EXT and
PRESET/REGEN switches, in assemble editing
only, the timecode generator regenerates according
to the timecode on the tape.
MANU: Regardless of whether this unit is the
recorder or player, the timecode generator operates
in accordance with the setting of the INT/EXT and
PRESET/REGEN switches.
FULL: Regardless of whether local or remote, when
any of the ASSEMBLE, VIDEO, AUDIO CH-1 to
CH-4, and TC buttons is lit, the timecode generator
regenerates according to the timecode played back
from the tape.