INSTALLER GUIDE
cables in position. Apply tension to the cables by turning the hexagonal adjusters by
hand (See figure 20).
13. Inspect the installation of the convection box against the fireplace surround. If the
convection box is aligned squarely and the sealing is satisfactory, fully tighten the
cable retainers.
14. If the convection box is not correctly aligned, release the tension on the cables by
slackening the screws and turning the
hexagonal adjusters fully anticlockwise. The
convection box should then automatically
realign itself. Pull each cable taut again and
push the cable retainers back against the
back panel. Again, tighten the screws in the
retainers and apply tension to the cables by
turning the hexagonal adjusters clockwise as
far as possible.
15. Feed the free length of the cables through
the small holes in the back of the convection
box immediately below the cable adjusters so
that they are available to allow easy removal
and refitting of the appliance during
subsequent service calls. Do not cut off the
free lengths of cable (See figure 20).
Figure 15. Front fixing

12.3 Sealing floor front - All installations.

Using the floor sealing tape supplied, seal the bottom of the convection box to the
fireplace and hearth floor (See figure 21).
Make sure that the whole length of the front edge of the convection box is fully
sealed.
A second strip of floor sealing tape is supplied. Use this to seal any small holes that
remain at the lower rear and sides of the convection box.
Figure 16. Eyebolt positions
©