10. Drill a hole into the fireplace floor
through each of the two holes in the
base of the convection box using a
no.12 masonry drill. See figure 18.
11. Insert a fibre plug into each hole.
Use the rawlplugs supplied with this
appliance - Never use plastic plugs
instead of the fibre plugs supplied. Fit
a woodscrew in each plug and tighten.
12. Inspect the installation of the
Figure 18. Floor Fixing
convection box against the fireplace
surround. If the convection box is
aligned squarely and the sealing is satisfactory, fully tighten the cable retainers.
13. If the convection box is not correctly aligned, release the tension on the cables by
slackening the screws and turning the hexagonal adjusters fully anticlockwise. The
convection box should then automatically realign itself. Pull each cable taut again and
push the cable retainers back against the "V" brackets. Again, tighten the screws in the
retainers and apply tension to the cables by turning the hexagonal adjusters clockwise as
far as possible.
14. Push the free length of the cables inside the convection box so that they are
available to allow easy removal and refitting of the appliance during subsequent service
calls.
9.3

Floor Sealing

Using the floor sealing tape supplied,
seal the bottom of the convector box
to the fireplace and hearth floor. Run
the tape over the centre bracket.
Figure 19. Floor Sealing