Advertisement

MODEL 736XN
FOR USE WITH NATURAL GAS
INSTALLER'S & OWNER'S MANUAL
INSTALLER – PLEASE LEAVE THIS MANUAL WITH THE HOME OWNER
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
liquids in the vicinity of this or any other appliance.
WARNING:
Improper installation, adjustment,
alteration, service or maintenance can cause injury
or property damage. Refer to this manual. For
assistance or additional information consult a
qualified installer, service agency or the gas
supplier.
Massachusetts: The gas piping and the final gas
connection must be performed by a licensed
plumber or gas fitter in the State of Massachusetts.
Vous pourrez vous procurer un exemplaire en langue française de cette brochure chez votre concessionnaire.
Legend
WHAT TO DO IF YOU SMELL GAS
Open windows
T
Do not try to light any appliance
T
Do not touch any electrical switches
T
Do not use any phone in your building
T
Extinguish any open flame
T
Immediately call your gas supplier from a
T
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
T
fire department.
Installation of this appliance in a bedroom is
prohibited in the State of Massachusetts.
MODEL 736XP
FOR USE WITH PROPANE
FOR YOUR SAFETY
600A992/04

Advertisement

Table of Contents
loading

Summary of Contents for Valor Legend 736XN

  • Page 1 Legend MODEL 736XN MODEL 736XP FOR USE WITH NATURAL GAS FOR USE WITH PROPANE INSTALLER’S & OWNER’S MANUAL INSTALLER – PLEASE LEAVE THIS MANUAL WITH THE HOME OWNER FOR YOUR SAFETY FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not store or use gasoline or other flammable Open windows liquids in the vicinity of this or any other appliance.
  • Page 2 This appliance requires a source of fresh air in order Only the authorized Valor replacement window to vent properly. The venting system should be unit listed in the repair parts booklet must be fitted - checked periodically.
  • Page 3: Optional Accessories

    POSSIBLE INSTALLATION INSTRUCTIONS INSTALLATIONS OPTIONAL ACCESSORIES This appliance can be The following kits can be used with this appliance: installed either: #700ZCK Zero Clearance Kit – Required for use As an insert in an with a new zero clearance type installation (See existing solid fuel possible installations section following).
  • Page 4: High Altitude Installations

    As a zero clearance installation fitted with the optional part #700ZCK kit, the appliance may be installed into a minimum sized enclosure constructed of combustible building materials and connected to an approved type “B” vent. This kit (complete with full installation details) is available from your dealer.
  • Page 5: Pack Contents

    FLOOR The floor in the fireplace recess must be sufficiently flat and level to support the appliance satisfactorily. Some fireplace constructions have a well in the floor at the back, which may need to be filled in. Do not place the appliance on carpeting, vinyl or other soft-surface floor coverings.
  • Page 6: Optional Trim Installation

    2.1.6 Check Ignition Electrode Spark Pilot ignition is by a spark produced when the control knob is pushed in and turned counterclockwise to the “IGN” position. Check that two consecutive sparks are produced at the pilot burner. If there is no spark, check that the wiring is secure. Replace parts if necessary.
  • Page 7 2.3.2 #678FSK & #679FSK Swing the lower shaft forward and remove the collar ” Contoured Trims (figure 15c). Keep the collar safe. Assemble the left and Swing the lower shaft back and park it in the slot right side channels to opening in the right side of the appliance case (figure the top channel using 15d).
  • Page 8: Leak Testing

    LEAK TESTING Place the ceramic side walls in position at the sides of the firebox. The sides are left and right handed. The sides should be held in position at the top by the All piping and connections must be tested for leaks after angled brackets at the sides of the firebox and at the installation or servicing.
  • Page 9: Refit The Window

    REFIT THE WINDOW CHECK VENTING EFFICIENCY Hook the top of the window frame over the firebox A check for correct venting of combustion products must top front edge. be made before the installed appliance is left with the Secure the window unit in place by refitting two customer.
  • Page 10: Aeration Adjustment

    AERATION ADJUSTMENT OPERATING PROCEDURE Both front and rear burners For your safety this appliance is fitted with a flame are equipped with supervision device which will shut off the gas supply if, for adjustable shutters to any reason, the pilot flames go out. This device incorporates a control primary aeration.
  • Page 11: For Your Safety Read Before Lighting

    FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
  • Page 12 CLEANING SERVICING All cleaning should be carried out when the appliance is cold. The repair parts are shown on the repair parts leaflet. Please Normally the appliance should only need dusting. Dust etc. always quote part number and description with requests for can be brushed from the logs using a soft brush after detaching spares.
  • Page 13 Figure 27. Burner Module Removal...
  • Page 14 Manufactured by HEATING BIRMINGHAM, ENGLAND Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. © Valor Ltd. 1999, 2000...

This manual is also suitable for:

Legend 736xp