Sealing Floor Front - Method 1 & 2 Inc Frameless - Valor Inspire 600FS Installer And Owner Manual

Hide thumbs Also See for Inspire 600FS:
Table of Contents

Advertisement

INSTALLER GUIDE
used, insert the convection box into the fireplace feeding the supply pipe through the
pierced hole in the rear grommet.
7. Thread the cables through the eyebolts. Return the cables through the holes near
the bottom of the convection box back panel.
8. Fit a cable retainer over the bottom end of each cable.
9. Pull each cable taut. Push the cable retainers hard up against the back panel. The
end of the cable adjuster will pass into the hole. Tighten the screws in the retainers so
that they clamp the cables in position. Apply tension to the cables by turning the
hexagonal adjusters by hand.
10. Inspect the installation of the convection box against the fireplace surround. If the
convection box is aligned squarely and the sealing is satisfactory, fully tighten the
cable retainers.
11. If the convection box is not correctly aligned, release the tension on the cables by
slackening the screws and turning the hexagonal adjusters fully anticlockwise. The
convection box should then automatically realign itself. Pull each cable taut again and
push the cable retainers back against the back panel. Again, tighten the screws in the
retainers and apply tension to the cables by turning the hexagonal adjusters
clockwise as far as possible.
12.
Feed the free length of the cables through the small holes in the back of the
convection box immediately below the cable adjusters so that they are available to
allow easy removal and refitting of the appliance during subsequent service calls.
Do not cut off the free lengths of cable.
11.3 Sealing floor front and holes
Using the floor sealing tape supplied, seal
the bottom of the convection box to the
fireplace and hearth floor.
Make sure that the whole length of the
front edge of the convection box is
fully sealed.
A second strip of floor sealing tape is
Floor Sealing
supplied. Use this to seal any small holes
that remain at the lower rear and sides of the
convection box.
NOTE: If fitting the convector box fitted with a
frameless kit the sealing tape has already have
been fitted across the base of the frameless trim
and the base surface of the convector box. Check
to ensure this tape has not been damaged in
transit or handling.
An additional strip of foam seal placed directly
along the middle of this silver sealing tape is
necessary before installation to ensure a seal to
Frameless foam seal position
the base of the floor.
©