Siemens SINAMICS S120 Manual page 359

Chassis power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Preparatory steps
● Disconnect the drive line-up from the power supply
● Allow unimpeded access
● Remove the front cover
Removal
The removal steps are numbered in accordance with the numbers in the diagram.
1. Disconnect the plugs for the signal cables (two connectors).
2. Remove DRIVE-CLiQ cables and connections at –X41/–X42/–X46 (six connectors).
3. Take out the retaining screws for the IPD card (two screws) and remove the IPD card
4. Remove the retaining screws for the Control Interface Module (two screws).
When removing the Control Interface Module, you have to disconnect five additional plugs
one after the other (two at the top, three below).
NOTICE
Do not damage any signal cables
When removing, ensure that you do not damage any signal cables.
Installation steps
Installing is the same as removing, however in the reverse order.
NOTICE
Specifications for the installation
The tightening torques specified in the table "Tightening torques for screw connections"
must be observed.
Carefully insert the plug connections and ensure that they are secure.
Chassis power units
Manual, (GH3), 01/2013, 6SL3097-4AE00-0BP3
The DRIVE-CLiQ cables should be marked to ensure that they are subsequently correctly
inserted.
from plug -X45 on the Control Interface Module.
Maintenance and Servicing
8.4 Replacing components
357

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents