Motor-side power components
6.3 dv/dt filter plus Voltage Peak Limiter
Table 6- 25
Technical data of the dV/dt filter plus voltage peak limiter, 3 AC 380 ... 480 V, Part 3
Order number
Suitable for Motor Module
Type rating of the Motor
Module
I
thmax
Degree of protection
dV/dt reactor
Power loss
- At 50 Hz
- At 60 Hz
- At 150 Hz
Connections
- To the Motor Module
- Load
- PE
Max. permissible cable
length between dV/dt
reactor and motor
Dimensions
Width
Height
Depth
Weight, approx.
Voltage peak limiter
Power loss
- At 50 Hz
- At 60 Hz
- At 150 Hz
Connections
- To the dV/dt reactor
- DC
- PE
Dimensions
Width
Height
Depth
Weight, approx.
Two dV/dt reactors are required for these dV/dt filters. The technical data provided applies to one dV/dt reactor.
1)
Note
Cable lengths for versions with two dV/dt reactors
For versions with 2 dV/dt reactors, the cable lengths specified in the table do not change.
278
6SL3000-
2DE41-4AA0
6SL3320-
1TE41-0AAx
kW
560
A
1405
IP00
kW
1.111
kW
1.154
kW
1.23
2 x M12
2 x M12
M6
m
mm
445
mm
385
mm
312
kg
158
kW
0.134
kW
0.125
kW
0.114
M10
M10
M8
mm
309
mm
1312.5
mm
400
kg
72
2DE41-4AA0
1)
1)
1TE41-2AAx
710
1405
IP00
1.111
1.154
1.23
2 x M12
2 x M12
M6
300 (shielded)
450 (unshielded)
445
385
312
158
0.134
0.125
0.114
M10
M10
M8
309
1312.5
400
72
Manual, (GH3), 01/2013, 6SL3097-4AE00-0BP3
2DE41-4AA0
1)
1TE41-4AAx
800
1405
IP00
1.111
1.154
1.23
2 x M12
2 x M12
M6
445
385
312
158
0.134
0.125
0.114
M10
M10
M8
309
1312.5
400
72