Technical Data - Siemens SINAMICS S120 Manual

Chassis power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

DC link components
5.2 Braking resistors
5.2.5

Technical data

Table 5- 8
Technical data, braking resistors, 380 V ... 480 V 3 AC
Order number
P
(rated power)
DB
P
(peak power)
15
Max. current
Resistance
Cable entry
Power connection
Max. connectable cable cross-section
Degree of protection
Width x height x depth
Weight, approx.
Table 5- 9
Technical data, braking resistors, 500 V ... 600 V 3 AC
Order number
P
(rated power)
DB
P
(peak power)
15
Max. current
Resistance
Cable entry
Power connection
Max. connectable cable cross-section
Degree of protection
Width x height x depth
Weight, approx.
Table 5- 10
Technical data, braking resistors, 660 V ... 690 V 3 AC
Order number
P
(rated power)
DB
P
(peak power)
15
Max. current
Resistance
Cable entry
Power connection
Max. connectable cable cross-section
Degree of protection
Width x height x depth
Weight, approx.
246
Unit
6SL3000-1BE31-3AA0
kW
kW
A
Ω
4.4 (± 7,5 %)
via M50 cable gland
via M8 bolt-type terminal
mm²
mm
740 x 605 x 485
kg
Unit
6SL3000-1BF31-3AA0
kW
kW
A
Ω
6.8 (± 7,5 %)
via M50 cable gland
via M8 bolt-type terminal
mm²
mm
740 x 605 x 485
kg
Unit
6SL3000-1BH31-3AA0
kW
kW
A
Ω
9.8 (± 7,5 %)
via M50 cable gland
via M8 bolt-type terminal
mm²
mm
740 x 605 x 485
kg
25
125
189
via M10 bolt-type terminal
50
IP20
50
25
125
153
via M10 bolt-type terminal
50
IP20
50
25
125
125
via M10 bolt-type terminal
50
IP20
50
Manual, (GH3), 01/2013, 6SL3097-4AE00-0BP3
6SL3000-1BE32-5AA0
50
250
378
2.2 (± 7,5 %)
via M50 cable gland
70
IP20
810 x 1325 x 485
120
6SL3000-1BF32-5AA0
50
250
306
3.4 (± 7,5 %)
via M50 cable gland
70
IP20
810 x 1325 x 485
120
6SL3000-1BH32-5AA0
50
250
255
4.9 (± 7,5 %)
via M50 cable gland
70
IP20
810 x 1325 x 485
120
Chassis power units

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents