Siemens SINAMICS S120 Manual page 301

Chassis power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Table 6- 36
Technical data of the dV/dt filter compact plus voltage peak limiter, 380 V ... 480 V 3 AC, Part 2
Order number
Suitable for Motor Module
(unit rating)
I
thmax
Degree of protection
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
Max. permissible cable
length between dV/dt filter
and motor
dV/dt reactor
Terminals
- 1U1/1V1/1W1
- 1U2/1V2/1W2
- PE
Dimensions
Width
Height
Depth
Weight, approx.
Voltage peak limiter
Terminals
- DCPS/DCNS
- 1U2/1V2/1W2
- PE
Dimensions
Width
Height
Depth
Weight, approx.
Chassis power units
Manual, (GH3), 01/2013, 6SL3097-4AE00-0BP3
6SL3000-
2DE41-4EA0
6SL3320-
1TE41-0AAx (560 kW)
1TE41-2AAx (710 kW)
1TE41-4AAx (800 kW)
A
1405
IP00
kW
1.154
kW
1.197
kW
1.444
m
for 2 x M12 bolts
for 2 x M12 bolts
M6 screw
mm
430
mm
385
mm
323
kg
168.8
for M8 bolt
for M8 bolt
for M6 screw
mm
277
mm
360
mm
291
kg
19.2
Motor-side power components
6.4 dv/dt filter compact plus Voltage Peak Limiter
100 (shielded)
150 (unshielded)
299

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents