Siemens SINAMICS S120 Manual page 266

Chassis power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor-side power components
6.3 dv/dt filter plus Voltage Peak Limiter
Table 6- 16
Table 6- 17
264
Max. pulse frequency when a dV/dt filter is used in units with a rated
pulse frequency of 2 kHz
Order no.
Power
6SL3320-...
[kW]
1TE32-1AAx
110
1TE32-6AAx
132
1TE33-1AAx
160
1TE33-8AAx
200
1TE35-0AAx
250
Max. pulse frequency when a dV/dt filter is used in units with a rated
pulse frequency of 1.25 kHz
Order no.
Power
6SL3320-...
[kW]
1TE36-1AAx
315
1TE37-5AAx
400
1TE38-4AAx
450
1TE41-0AAx
560
1TE41-2AAx
710
1TE41-4AAx
800
1TG28-5AAx
75
1TG31-0AAx
90
1TG31-2AAx
110
1TG31-5AAx
132
1TG31-8AAx
160
1TG32-2AAx
200
1TG32-6AAx
250
1TG33-3AAx
315
1TG34-1AAx
400
1TG34-7AAx
450
1TG35-8AAx
560
1TG37-4AAx
710
1TG38-1AAx
800
1TG38-8AAx
900
1TG41-0AAx
1000
1TG41-3AAx
1200
Output current for a
pulse frequency of 2 kHz
[A]
Supply voltage 510 – 750 VDC
210
260
310
380
490
Output current for a
pulse frequency of 1.25
kHz [A]
Supply voltage 510 – 750 VDC
605
745
840
985
1260
1405
Supply voltage 675 – 1080 VDC
85
100
120
150
175
215
260
330
410
465
575
735
810
910
1025
1270
Manual, (GH3), 01/2013, 6SL3097-4AE00-0BP3
Max. pulse frequency when a
dV/dt filter is used
4 kHz
4 kHz
4 kHz
4 kHz
4 kHz
Max. pulse frequency when a
dV/dt filter is used
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
Chassis power units

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents