Preparation
To calculate a value in percent, the reference percentage must be known.
This value can be entered into the weighing-in-percent program in one of three ways:
– The last reference percentage entered is loaded and displayed when you turn on the scale.
Place the corresponding weight on the scale and initialize the weighing-in-percent program;
– With automatic initialization switched on (see previous page), the scale goes into the
"weighing in percent" mode when you turn on the power and loads the last reference
percentage entered as well as the corresponding reference weight (Setup: Printout:
Application-defined output: Auto print upon initialization: All values);
– Enter the reference weight using the numeric keys and store it (
§ Turn on the scale: press e
> Sartorius logo is displayed, self-test is performed
§ Select the "Weighing in percent" application in the Setup menu: press H
§ Select
Application parameters
then the
soft key once
O
§ Select
Application 1 (basic settings)
§ Select
Percent weigh.
§ Confirm
Percent weigh.
§ Select and confirm:
Weighing in
Accuracy weight
percent
storage
(resolution)
Decimal places for
readout in percent
Display calculated
value
o = factory setting
see also the "Application Menu (Overview)" in the chapter entitled "Configuration"
Save settings and exit the Setup menu: Press soft key
Equations
The following equations are used for the corresponding calculations:
Residue = Current weight ÷ 100% weight x 100%
Loss
= (Current weight – 100% weight) ÷ 100% weight x 100%
Ratio1
= (100% weight – current weight) ÷ current weight x 100%
Ratio2
= 100% weight ÷ current weight x 100%
52
: press the
soft key 2+,
q
: press the
:
or
soft key repeatedly
Q
q
:
soft key
O
o Display accuracy
+1 decimal place
+2 decimal places
None
1 decimal place
o 2 decimal places
3 decimal places
4 decimal places
5 decimal places
6 decimal places
o Residue qty.
Loss
Ratio1 (DR)
Ratio2 (OR)
oo
Wxx%
soft key).
O
soft key
Additional Functions
In addition to the functions for:
– alphanumeric input,
– taring (not during alphanumeric input),
– printing,
you can also access the following
functions from this application:
Calibration/Adjustment
isoTST
Press the
soft key
> See "Calibration/Adjustment" for
further instructions
Toggling to the Next Application
Press D
> See the section on the corresponding
application program for further
instructions
Setup (setting parameters )
Press H
> See "Configuration" for further
instructions
Turning Off the Scale
Press e
> The scale shuts off