Weighing in Percent

Purpose
This application program allows you
to obtain weight readouts in percent
which are in proportion to a reference
weight. Alternatively, you can have
the value displayed as a difference in
percent between the weight on the
scale and the reference weight, or as
a special ratio 1 or ratio 2.
You can use this application program
in combination with a program chosen
from Application 2 (checkweighing,
time-controlled functions) and one
from Application 3 (totalizing, formula-
tion, statistics).
B
Available Features
– Reference percentage "pRef" loaded
from long-term memory when you turn
on the scale
– Optional scale configuration in Setup
for automatically initializing this
application and loading the most
recent reference percentage "pRef"
entered with reference weight
"Wxx%" when you turn on the scale
– Value displayed as:
– Residual quantity (portion)
– Difference (deviation)
– Ratio1
– Ratio2
depending on the Setup menu code
selected.
– Reference percentage "nRef" entered
manually
– Store the current weight as the
reference percentage weight "Wxx%"
for initializing the weighing-in-percent
application program
– Reference weight "Wxx%" entered
manually
– Storage parameter (rounding-off factor)
for storing the reference weight
"W100%" in percentage calculation
can be configured
– Configuration of decimal places
displayed with a percentage
– Optional configuration for having the
reference weight "Wxx%" and reference
percentage automatically output via the
data interface port after initialization
of the weighing-in-percent program
(print application parameters)
– Toggle the display between percentage
and weight readout by pressing the
Weigh.
soft key
– Toggle between the weighing-in-
percent program and other applications
(e.g., checkweighing) by pressing D
Factory Settings
Storage parameter:
Display accuracy
Digits displayed with percentage:
2 digits
Display calculated value:
Residue
Soft Key Functions
pRef
Store value input as
reference percentage
Wxx%
Store input value as
reference sample weight
Perc.
Toggle to the Weighing-
in-percent application
New
Store next value
Weigh.
Toggle to the Weighing
mode
Start
Store the current weight
value for the preset
reference sample quantity