IP Address:
Primary DNS:
Secondary DNS:
You would need to issue the following commands from the command line:
# /bin/config --set=config.interfaces.wan.mode=static
# /bin/config --set=config.interfaces.wan.address=192.168.1.100
# /bin/config --set=config.interfaces.wan.netmask=255.255.255.0
# /bin/config --set=config.interfaces.wan.gateway=192.168.1.1
# /bin/config --set=config.interfaces.wan.dns1=192.168.1.254
# /bin/config --set=config.interfaces.wan.dns2=10.1.0.254
The following command will synchronize the live system with the new configuration:
# /bin/config –-run=ipconfig
14.4.2

Dial-In Configuration

To enable dial-in access on the DB9 serial port from the command line with the following
attributes:
Local IP Address
Remote IP Address
Authentication Type:
Serial Port Baud Rate:
Serial Port Flow Control:
Custom Modem Initialization:
You would need to issue the following commands from the command line to set system
configuration:
# /bin/config –-set=config.console.ppp.localip=172.24.1.1
# /bin/config –-set=config.console.ppp.remoteip=172.24.1.2
# /bin/config –-set=config.console.ppp.auth=MSCHAPv2
# /bin/config –-set=config.console.ppp.enabled=on
# /bin/config –-set=config.console.speed=115200
192.168.1.100
192.168.1.254
10.1.0.254
172.24.1.1
172.24.1.2
MSCHAPv2
115200
Hardware
ATQ0V1H0
173