Check Log Status and specify the Log Rate (i.e. minutes between samples) if you wish the status
from this UPS to be logged. These logs can be views from the Status: UPS Status screen.
Check Enable Nagios to enable this UPS to be monitored using Nagios central management.
Click Apply.
You can also customize the upsmon, upsd and upsc settings for this UPS hardware directly from the
command line.

8.2.2 Configure UPS Powering the Console Server

A Monitored UPS is a UPS that is providing the power to the Console Server. The purpose of configuring
a Monitored UPS is to provide an opportunity to perform any "last gasp" actions before power is lost
during a power failure. This is achieved by placing a script in /etc/config/scripts/ups-shutdown. You may
use the /etc/scripts/ups-shutdown as a template. This script is run when then UPS reaches critical
battery status.
 If the Console Server is drawing power through a Managed UPS that has already been
configured, select Local, enter the Managed UPS Name and check Enabled. The Console Server
continues to be the master of this UPS.
 If the UPS that powers the Console Server is not a Managed UPS for that Console Server, then
the Console Server can still connect to a remote NUT server (upsd) to monitor its status as a
Slave. In this case, select Remote, and enter the address, username and password to connect.
118