S600 Series - Manitowoc S300 Technician's Handbook

S series
Table of Contents

Advertisement

S600 SERIES

S600A
All Self-Contained Air-Cooled Models
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser
°F/°C
70/21
80/27
90/32
100/38
1 Times in minutes
24 HOUR ICE PRODUCTION
Air Temp. Entering
Condenser °F/°C
70/21
80/27
90/32
100/38
1 Based on average ice slab weight of 4.12-4.75 lb.
OPERATING PRESSURES
Air Temp
Entering
Condenser
°F/°C
50/10
70/21
80/27
90/32
100/38
110/43
1 Suction pressure drops gradually throughout the freeze cycle
Part Number 80-1479-3 7/10
Water Temperature °F/°C
50/10.0
7.6-9.0
7.8-9.2
8.6-10.1
9.9-11.7
Freeze Cycle
Discharge
Suction
Pressure
Pressure
PSIG
220-255
220-270
230-300
265-345
300-395
340-430
Freeze Time
70/21.1
8.4-9.9
8.8-10.3
9.5-11.2
10.9-12.8
Water Temperature °F/°C
50/10.0
70/21.1
650
640
590
520
Discharge
Pressure
PSIG
45-27
140-160
45-28
145-170
50-30
165-185
54-32
180-215
60-35
210-245
65-39
240-280
Harvest
90/32.2
9.1-10.7
9.3-10.9
10.2-11.9
11.4-13.4
90/32.2
600
580
540
480
Harvest Cycle
Suction
Pressure
PSIG
PSIG
60-80
70-90
75-95
80-105
85-120
100-140
1
Time
1-2.5
1
560
550
510
460
1
215

Hide quick links: