Safety Timers - Manitowoc S300 Technician's Handbook

S series
Table of Contents

Advertisement

Safety Timers

The control board has the following non-adjustable
safety timers:
The ice machine is locked into the freeze cycle for
6 minutes before a harvest cycle can be initiated.
Freeze lock is bypassed after moving the toggle
switch from OFF to ICE position for the first cycle
only.
The maximum freeze time is 60 minutes at which
time the control board automatically initiates a
harvest sequence (steps 5 & 6).
The maximum harvest time is 3.5 minutes for
single evaporators and 7 minutes for Quad
evaporator model. The control board automatically
initiates a freeze sequence (steps 3 & 4) when
these times are exceeded.
64
Part Number 80-1479-3 7/10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents