PERSONAL INJURY POTENTIAL
Remove a ll i ce machi ne p anels before lifting a nd
installing.
Location of Ice Machine
The location selected for the ice machine head section
must meet the following criteria. If any of these criteria
are not met, select another location.
•
The location must be free of airborne and other
contaminants.
•
Self contained air and water cooled - The air
temperature must be at least 35°F (1.6°C), but
must not exceed 110°F (43.4°C).
•
Remote air cooled - The air temperature must be
at least -20°F (-29°C), but must not exceed 120°F
(49°C)
•
Ice Making Water Inlet - Water Pressure must be
at least 20 psi (1.38 bar), but must not exceed 80
psi (5.52 bar).
•
Condenser Water Inlet - Water Pressure must be
at least 20 psi (1.38 bar), but must not exceed
150 psi (10.34 bar). S3300W-HP units allow water
pressure up to 350 psig (24.13 bar)
•
The location must not be near heat-generating
equipment or in direct sunlight and protected from
weather.
•
The location must not obstruct air flow through or
around the ice machine. Refer to chart below for
clearance requirements.
•
The ice machine must be protected if it will be
subjected to temperatures below 32°F (0°C).
Failure caused by exposure to freezing
temperatures is not covered by the warranty. See
"Removal from Service/Winterization"
Part Number 80-1479-3 7/10