Water Dump Valve - Manitowoc S300 Technician's Handbook

S series
Table of Contents

Advertisement

Water Dump Valve

The water dump valve normally does not require
removal for cleaning. To determine if removal is
necessary:
1. Locate the water dump valve.
2. Set the toggle switch to ICE.
3. While the ice machine is in the freeze mode,
check the water trough to determine if the dump
valve is leaking. If there is no or little water in the
water trough (during the freeze cycle) the dump
valve is leaking.
A. If the dump valve is leaking, remove,
disassemble and clean it.
B. If the dump valve is not leaking, do not
remove it. Instead, follow the "Ice Machine
Cleaning Procedure".
Follow the procedure below to remove the dump
valve.
Disconnect the electric power to the ice ma chine
at the electric service switch bo x and turn off the
water supply before proceeding.
4. If so equipped, remove the water dump valve
shield from its mounting bracket.
5. Leaving the wires attached, twist coil and rotate it
counter-clockwise1/4 turn.
6. Lift the coil assembly off the valve body.
7. Remove the spring, plunger, and nylon gasket
from the valve body.
At this point, the water dump valve can easily
NOTE:
be cleaned. If complete removal is desired, continue
with step 5.
The plunger and the inside of the enclosing tube
must be completely dry before assembly.
54
Warning
!
Important
Part Number 80-1479-3 7/10