All Remote Air-Cooled Condenser Models
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser
°F/°C
-20/-29 to 70/21
80/27
90/32
100/38
110/43
1 Times in minutes
24 HOUR ICE PRODUCTION
Air Temp. Entering
Condenser
°F/°C
-20/-29 to 70/21
80/27
90/32
100/38
110/43
1 Based on average ice slab weight of 4.12 - 4.75 lb
2 Ratings with JC0895 condenser dice or half dice cubes
OPERATING PRESSURES
Air Temp.
Entering
Condenser
°F/°C
-20/-29 to
50/10
70/21
80/27
90/32
100/38
110/43
1 Suction pressure drops gradually throughout the freeze cycle
Part Number 80-1479-3 7/10
Water Temperature °F/°C
50/10
7.9-9.4
7.9-94
8.1-9.5
8.8-10.3
9.7-11.4
Freeze Cycle
Discharge
Pressure
Pressure
PSIG
210-240
225-250
245-275
245-285
260-315
290-365
Freeze Time
70/21
8.8-10.3
8.9-10.5-
8.9-10.5
9.7-11.4
10.6-12.5
Water Temperature °F/°C
50/10
630
630
620
580
530
Suction
Discharge
Pressure
PSIG
40-29
130-190
50-30
130-200
52-31
130-200
52-32
135-200
55-32
140-200
60-34
170-200
Harvest
90/32
9.3-10.9
9.5-11.2
9.7-11.4
10.4-12.2
11.4-13.4
70/21
580
570
570
530
490
Harvest Cycle
Suction
Pressure
PSIG
PSIG
62-80
75-95
75-100
80-100
80-100
85-100
1
Time
1-2.5
12
90/32
550
530
540
500
460
1
217