Cycle Time/24 Hour Ice Production/Refrigerant Pressure Charts; S600M Series - Manitowoc S600M Service Manual

Hide thumbs Also See for S600M:
Table of Contents

Advertisement

Refrigeration System
Cycle Time/24 Hour Ice Production/
Refrigerant Pressure Charts
These charts are used as guidelines to verify correct ice
machine operation.
Accurate collection of data is essential to obtain the
correct diagnosis.
Refer to "OPERATIONAL ANALYSIS TABLE" for the
list of data that must be collected for refrigeration
diagnostics. This list includes: before beginning
service, ice production check, installation/visual
inspection, water system checklist, ice formation
pattern, safety limits, comparing evaporator inlet/
outlet temperatures, discharge and suction pressure
analysis.
Ice production checks that are within 10% of the
chart are considered normal. This is due to variances
in water and air temperature. Actual temperatures
will seldom match the chart exactly.
Zero out manifold gauge set before obtaining
pressure readings to avoid misdiagnosis.
Discharge and suction pressure are highest at the
beginning of the cycle. Suction pressure will drop
throughout the cycle. Verify the pressures are within
the range indicated.
Record beginning of freeze cycle suction pressure
one minute after water pump energizes.
Regular cube production derate is 7%
50Hz production derate is 7%
7-20

S600M SERIES

Self-Contained Water-Cooled
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Around Ice
Water Temperature °F/°C
Machine
50/10.0
°F/°C
70/21.1
7.6-9.0
80/26.7
7.8-9.2
90/32.2
7.9-9.4
100/37.8
8.1-9.5
Times in minutes
24 Hour Ice Production
Air Temp.
Water Temperature °F/°C
Around Ice
Machine
50/10.0
°F/°C
70/21.1
650
80/26.7
640
90/32.2
630
100/37.8
620
Based on average ice slab weight of 4.12 - 4.75lb
Operating Pressures
Freeze Cycle
Air Temp.
Around Ice
Discharge
Machine
Pressure
°F/°C
PSIG
50/10.0
225-235
70/21.1
225-235
80/26.7
225-245
90/32.2
230-255
100/37.8
230-260
110/43.3
230-260
Suction pressure drops gradually throughout the freeze cycle
Section 7
Freeze Time
70/21.1
90/32.2
7.9-9.4
8.6-10.1
8.1-9.5
8.8-10.3
8.2-9.7
8.8-10.3
8.4-9.9
9.1-10.7
70/21.1
90/32.2
630
620
610
600
Harvest Cycle
Suction
Discharge
Pressure
Pressure
Pressure
PSIG
PSIG
36-26
140-190
36-26
140-190
40-28
150-195
40-29
160-200
40-30
170-205
40-30
180-210
Part Number 80-1630-3
Harvest
Time
1-2.5
590
580
580
560
Suction
PSIG
65-95
65-95
70-100
70-100
75-105
80-110

Advertisement

Table of Contents
loading

Table of Contents