Diagnosing Ice Thickness Control Circuitry

PROBLEM: ICE MACHINE DOES NOT CYCLE INTO
HARVEST WHEN WATER CONTACTS THE ICE
THICKNESS CONTROL PROBE
Step 1 Bypass the freeze time lock-in feature by
moving the ICE/OFF/CLEAN switch to OFF and back
to ICE.
Step 2 Wait until water starts to flow over the
evaporator (freeze cycle).
Step 3 Disconnect the ice thickness control from the
control board, then connect a jumper wire from the
control board to any cabinet ground and monitor the
ice probe light.

Ice Probe Light On

The ice probe light comes on, and 10 seconds
later, the ice machine cycles from Freeze to
Harvest.
The ice thickness probe is causing the
malfunction.
The ice probe light comes on, but the ice machine
stays in the Freeze sequence.
The control board is causing the malfunction.

Ice Probe Light Off

The ice probe light does not come on.
The control board is causing the malfunction.
If you suspect a defective probe check for continuity
from the ice thickness probe to the connector.
With continuity DO NOT change the probe.
Without continuity, the probe is defective.
148
Part Number 80-1479-3 7/10