WATER TROUGH OVERFILLING CONTINUED

Step 3. Jumper Wire Connected from
Control Board Terminal to Ground
Is Water
Flowing
into the
Water
Trough?
No
Yes
Yes
Part Number 80-1479-3 7/10
The
Water
Level
Light Is:
On
De-energized
Off
On
De-energized
The Water
Inlet Valve
Solenoid
Coil Is:
Energized
Cause
The water level
probe is
causing the
problem. Ohm,
then clean or
replace the
water level
probe.
The control
board is
causing the
problem.
The water fill
valve is
causing the
problem.