Manitowoc S300 Technician's Handbook page 224

S series
Table of Contents

Advertisement

S850N Remote Air-cooled Condenser
All Remote Condenser Air-Cooled Before Serial Number
110682385
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser
°F/°C
-20/-29 to 70/21
80/27
90/32
100/38
110/43
1 Times in minutes
24 HOUR ICE PRODUCTION
Air Temp. Entering
Condenser
°F/°C
-20/-29 to 70/21
80/27
90/32
100/38
110/43
1 Based on average ice slab weight of 5.75 -6.50 lb
2 Ratings with JC0895 condenser
OPERATING PRESSURES
Air Temp.
Entering
Condenser
°F/°C
-20/-29 to
50/10
70/21
80/27
90/32
100/38
110/43
1 Suction pressure drops gradually throughout the freeze cycle
224
Water Temperature °F/°C
50/10
8.6-9.9
8.9-10.2
9.1-10.5
9.8-11.3
10.9-12.5
Freeze Cycle
Discharge
Pressure
Pressure
PSIG
220-250
220-260
240-265
250-280
280-320
310-365
Freeze Time
70/21
9.1-10.5
9.5-11.0
9.8-11.3
10.7-12.3
11.9-13.6
Water Temperature °F/°C
50/10
820
800
780
730
670
Suction
Discharge
Pressure
PSIG
50-30
100-160
50-30
100-160
50-30
100-160
52-30
100-160
56-30
110-165
62-31
125-170
Part Number 80-1479-3 7/10
Harvest
90/32
9.7-11.1
10.0-11.5
11.3-11.9
11.2-12.9
12.5-14.4
70/21
780
750
730
680
620
Harvest Cycle
Suction
Pressure
PSIG
PSIG
70-90
70-90
75-90
75-95
75-95
80-100
1
Time
1-2.5
12
90/32
740
720
700
650
590
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents