S0600C/Cvd0675 Series Remote Air Cooled - Manitowoc QuietQube SD0672C Technician's Handbook

S model & ice beverage ice machines
Hide thumbs Also See for QuietQube SD0672C:
Table of Contents

Advertisement

S0600C/CVD0675 SERIES REMOTE AIR COOLED

NOTE: These characteristics may vary depending on
operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Entering
Condenser
°F/°C
-20 to 70/
-29 to 21
80/27
90/32
100/38
110/43
1
Times in minutes.
24-HOUR ICE PRODUCTION
Air Temp.
Entering
Condenser
°F/°C
-20 to 70/
-29 to 21
80/27
90/32
100/38
1
Based on average ice slab weight of 4.1-4.75 lb.
OPERATING PRESSURES
Air Temp.
Entering
Condenser
°F/°C
-20 to 50/
-29 to 10
70/21
80/27
90/32
100/38
110/43
240
Freeze Time
Water Temperature °F/°C
50/10
7.6-9.0
7.8-9.2
7.9-9.4
8.6-10.1
9.5-10.9
50/10
650
640
630
590
Freeze Cycle
Discharge
Pressure
Pressure
psig
200-250
235-255
245-275
250-290
270-320
300-360
70/21
8.4-9.9
8.6-10.1
8.8-10.3
9.4-11.2
10.2-11.9
10.6-12.5
11.4-13.4
Water Temperature °F/°C
70/21
600
590
580
540
Suction
Discharge
Pressure
psig
44-26
180-210
50-28
185-210
50-28
190-210
52-30
195-215
52-31
210-240
60-32
215-260
Part Number 80-1505-3 6/11
Harvest
90/32
9.1-10.7
9.3-10.9
.75-2.5
9.7-11.4
90/32
560
550
530
510
Harvest Cycle
Suction
Pressure
psig
65-85
65-90
75-100
75-105
80-110
85-115
Time
psig

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents