Manitowoc S300 Technician's Handbook page 244

S series
Table of Contents

Advertisement

SY1404A
Half Dice Cube, Self-Contained Air-Cooled With a
Manufacture Date of 0905 (May 2009) or Later
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser
°F/°C
70/21
80/27
90/32
100/38
110/43
1 Times in minutes
24 HOUR ICE PRODUCTION
Air Temp. Entering
Condenser °F/°C
70/21
80/27
90/32
100/38
110/43
1 Based on average ice slab weight of 10.25 - 11.5 lb.
OPERATING PRESSURES
Air Temp
Entering
Condenser
°F/°C
50/10
70/21
80/27
90/32
100/38
110/43
1 Suction pressure drops gradually throughout the freeze cycle
244
Water Temperature °F/°C
50/10
8.7-9.9
9.1-10.4
9.7-11.0
10.6-12.1
11.9-13.6
Freeze Cycle
Discharge
Suction
Pressure
Pressure
PSIG
220-280
220-280
240-290
260-330
300-370
330-410
Freeze Time
70/21
9.6-11.0
10.1-11.5
10.8-12.3
11.9-13.6
13.6-15.4
Water Temperature °F/°C
50/10
1450
1390
1320
1220
1100
Discharge
Pressure
PSIG
40-24
150-180
40-26
160-180
50-27
160-180
50-27
180-200
54-28
200-220
60-29
220-250
Part Number 80-1479-3 7/10
Harvest
90/32
10.2-11.6
10.8-12.3
11.6-13.2
0.75 - 2.5
12.8-14.6
14.7-16.7
70/21
90/32
1330
1270
1200
1100
980
Harvest Cycle
Suction
Pressure
PSIG
PSIG
70-90
70-90
70-90
80-100
90-115
100-130
1
Time
1
1260
1200
1130
1030
910
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents