Installation; Location Of Ice Machine; Leveling The Ice Machine - Manitowoc WELTBILT NEO 310 Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

Location of Ice Machine

The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met, select
another location.
The location must be indoors.
The location must be free of airborne and other
contaminants.
The air temperature must be at least 40°F (4°C), but
must not exceed 110°F (43°C).
The location must not be near heat-generating
equipment or in direct sunlight.
The location must be capable of supporting the weight
of the ice machine and a full bin of ice.
The location must allow enough clearance for water,
drain and electrical connections in the rear of the ice
machine.
The location must not obstruct airflow through or
around the ice machine (condenser airflow is in and
out the front). Refer to the chart below for clearance
requirements.
The location must not be near garbage or other
contaminants.
The ice machine must use legs or be sealed to the floor.
Before sealing to the floor, the rubber bumpers on the
bottom of the ice machine must be removed.
Self-Contained
Location
Air-Cooled
Top/Sides
5 (127 mm)
Back
5 (127 mm)
NOTE: The ice machine may be built into a cabinet. There
is no minimum clearance requirement for the top or left
and right sides of the ice machine. The listed values are
recommended for efficient operation and servicing only.
Part Number:040005890 Rev 06 11/20
Section 2

Installation

* B.T.U./Hour
** Because the heat of rejection varies during the ice
making cycle, the figure shown is an average.
Ice machines, like other refrigeration equipment, reject
heat through the condenser. It is helpful to know the
amount of heat rejected by the ice machine when sizing air
conditioning equipment where self-contained air-cooled
ice machines are installed.

LEVELING THE ICE MACHINE

1. Screw the leveling legs onto the bottom of the ice
2. Screw the foot of each leg in as far as possible.
3. Move the ice machine into its final position.
4. Level the ice machine by using a level on top of the ice
Self-Contained
Water-Cooled
5 (127 mm)
5 (127 mm)
Series
Ice Machine Heat of Rejection*
Ice Machine
Air Conditioning**
U140
2400
U190
2200
U240
2800
U310
3800
machine.
machine. Turn each foot as necessary to level the ice
machine from front to back and side to side.
Peak
2900
2600
3300
6000
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents