Location of Ice Machine

The location selected for the ice machine must meet
the following criteria. If any of these criteria are not
met, select another location.
The location must be indoors.
The location must be free of airborne and other
contaminants.
Air temperature:
Q130/Q170/Q210/Q270/QM45 must be at
least 40°F (4°C) but must not exceed 110°F
(43.4°C).
QM20/QM30 must be at least 50°F (10°C) but
must not exceed 113°F (45°C).
SM50 must be at least 50°F (10°C) but must
not exceed 110°F (43°C).
The location must not be near heat-generating
equipment or in direct sunlight.
The location must be capable of supporting the
weight of the ice machine and a full bin of ice.
The location must allow enough clearance for
water, drain, and electrical connections in the rear
of the ice machine.
The location must not obstruct airflow through or
around the ice machine (condenser airflow is in
and out the front). Refer to the chart below for
clearance requirements.
The ice machine must be protected if it will be
subjected to temperatures below 32°F (0°C).
Failure caused by exposure to freezing
temperatures is not covered by the warranty.
Part Number 8001119 10/19