Installation; Location Of Ice Machine; Installation Requirements - Manitowoc BG0260 Technician's Handbook

Spray cube
Table of Contents

Advertisement

LOCATION OF ICE MACHINE

The location selected for the ice machine must meet
the following criteria. If any of these criteria are not
met, select another location.
The location must be free of airborne and other
contaminants.
The location must not be near heat-generating
equipment or in direct sunlight.
The location must be capable of supporting the
weight of the ice machine and a full bin of ice.
The location must allow enough clearance for
water, drain and electrical connections in the rear
of the ice machine.
The location must not obstruct airflow through or
around the ice machine.

INSTALLATION REQUIREMENTS

The air temperature must be at least 50°F (10°C),
but must not exceed 110°F (43°C).
The water temperature must be at least 50°F
(10°C), but must not exceed 100°F (38°C).
The ice machine and bin must be level
Vent the ice machine and bin drains separately
Bin drain termination must have an air gap
A back flow preventer is required on water inlet
lines
Routine adjustments and maintenance procedures
outlined in this manual are not covered by the
warranty.
Part Number STH48 6/15