D Command table (continued)
Command
Sub command
1A
050035
050036
050037
050038
050039
050040
050041
050042
050043
050044
050045
050046
050047
050048
050049
050050
050051
050052
050053
050054
050055
050056
Description
Send/read the band selection for
operating frequency band signal
output to ACC-A. (0=MAIN,
1=SUB, 2=TX)
Send/read the band selection for
operating frequency band signal
output to ACC-A. (0=MAIN,
1=SUB, 2=TX)
Send/read relay type selection
(0=Lead, 1=MOS-FET)
Send/read main band's external
meter output selection (0=Auto,
1=S (main), 2=Po, 3=SWR,
4=ALC, 5=COMP, 6=V
, 7=I
)
D
D
Send/read sub band's external
meter output selection (0=Auto,
1=S (sub), 2=Po, 3=SWR,
4=ALC, 5=COMP, 6=V
, 7=I
)
D
D
Send/read main band's external
meter output level
(0=0% to 255=100%)
Send/read sub band's external
meter output level
(0=0% to 255=100%)
Send/read reference signal in/out
setting (0=OFF, 1=IN, 2=OUT)
Send/read reference signal fre-
quency setting
(0=0% to 255=100%)
Send/read LCD unit backlight
brightness (0=0% to 255=100%)
Send/read switch indicator bright-
ness (0=0% to 255=100%)
Send/read screen image type
(0=A, 1=B, 2=C)
Send/read frequency readout font
(0=Italic (1), 1=Italic (2), 2=Italic (3),
3=Italic (4), 4=Round (1),
5=Round (2), 6=Round (3),
7=Shadow (1), 8=Shadow (2),
9=Shadow (3), 10=Qubic (1),
11=Qubic (2), 12=Qubic (3),
13=Qubic (4), 14=IC-780 (1),
15=IC-780 (2), 16=IC-780 (3),
17=IC-780 (4))
Send/read font for other than fre-
quency readout
(0=Normal, 1=Slim)
Send/read meter type
(0=Standard, 1=Edgewise, 2=Bar)
Send/read meter type during wide
screen or mini scope indication
(0=Edgewise, 1=Bar)
Send/read peak hold set
(0=OFF, 1=ON)
Send/read memory name indica-
tion setting (0=OFF, 1=ON)
Send/read audio peak filter width
pop-up indication setting
(0=OFF, 1=ON)
Send/read manual notch width
pop-up indication setting
(0=OFF, 1=ON)
Send/read output signal setting for
external display (0=OFF, 1=ON)
Send/read synchronous pulse
level setting (0=L, 1=H)
Command
Sub command
1A
050057
050058
050059
050060
050061
050062
050063
050064
050065
050066
050067
050068
050069
050070
050071
050072
050073
050074
050075
050076
050077
050078
050079
050080
050081
050082
050083
050084
050085
050086
14-5
CONTROL COMMAND
Description
Send/read opening message indi-
cation (0=OFF, 1=ON)
Send/read opening message con-
tents (see p. 14-9 for details)
Send/read date (20000101=1st
Jan. 2001 to 20991231=31st Dec.
2099)
Send/read time (0000=00:00 to
2359=23:59)
Send/read clock 2 function
(0=OFF, 1=ON)
Send/read offset time for clock 2
(240001=–24:00 to 240000=+24:00)
Send/read clock 2 name (up to 3-
character; see p. 14-9)
Send/read calibration marker
(0=OFF, 1=ON)
Send/read confirmation beep
(0=OFF, 1=ON)
Send/read band edge beep
(0=OFF, 1=ON)
Send/read main band's beep
audio frequency
(50=500 Hz to 200=2000 Hz)
Send/read sub band's beep audio
frequency
(50=500 Hz to 200=2000 Hz)
Send/read quick dualwatch func-
tion (0=OFF, 1=ON)
Send/read quick split set (0=OFF,
1=ON)
Send/read FM split offset –9.999
to +9.999 MHz for HF
(see p. 14-10 for details)
Send/read FM split offset –9.999
to +9.999 MHz for 50 MHz
(see p. 14-10 for details)
Send/read split lock set (0=OFF,
1=ON)
Send/read tuner auto start set
(0=OFF, 1=ON)
Send/read PTT tune set (0=OFF,
1=ON)
Send/read transverter set
(0=OFF, 1=ON)
Send/read transverter offset (see
p. 14-10 for details)
Send/read RTTY mark frequency
(0=1275 Hz, 1=1615 Hz,
2=2125 Hz)
Send/read RTTY shift width
(0=170 Hz, 1=200 Hz, 2=425 Hz)
Send/read RTTY keying polarity
(0=Normal, 1=Reverse)
Send/read PSK tone frequency
(0=1000 Hz, 1=1500 Hz,
2=2000 Hz)
Send/read speech language
(0=English, 1=Japanese)
Send/read speech speed (0=Slow,
1=Fast)
Send/read S-level speech
(0=OFF, 1=ON)
Send/read speech with a mode
switch operation (0=OFF, 1=ON)
Send/read memo pad numbers
(0=5 ch, 1=10 ch)
14