Using the Built-in
Spectrum Analyzer
MDS 05-4846A01, Rev. C
4. To dekey the radio, select
the field at the right to
Figure 63. RF Keying Test Menu
(
Maintenance/Tools Menu>>Radio Test Menu>>RF Keying Test Menu
A unique feature of the transceiver is the ability to view the RF spectrum
above and below the operating frequency using its built-in Spectrum
Analyzer. Often, this can assist you in diagnosing the cause of interfer-
ence, or to view other signals near your operating frequency.
To use the Spectrum Analyzer, you must first specify a center frequency
and a span frequency. The center frequency is the frequency that you
wish the spectrum analysis display to be centered on. The span fre-
quency defines the width of the overall spectrum to be examined.
Follow these steps to use the spectrum analyzer:
1. Select
from the RF Test Menu to bring up the Spectrum
Spectrum
Analyzer screen (Figure 64).
2. Select
Center Frequency
and presents a flashing cursor.
3. Enter the frequency that you wish the spectral analysis to be cen-
tered on. Press the
4. Select
Span Frequency
and presents a flashing cursor.
5. Enter the frequency range that you wish to examine. Press the
key to apply the change.
ENTER
SD Series Ref. Manual (Packet & Transparent Mode)
again and use the spacebar to set
Key Radio
. Press the
OFF
ENTER
from the menu. The field to the right clears
key to apply the change.
ENTER
from the menu. The field to the right clears
key to apply the change.
)
81