Environmental Specifications; Noise Levels; Scsi Specifications; Table 47 Power - Quantum Scalar 50 User Manual

Scalar series tape library
Hide thumbs Also See for Scalar 50:
Table of Contents

Advertisement

Environmental Specifications

Table 47 Power

Table 48 Climate

Noise Levels

SCSI Specifications

Quantum Scalar 50 User's Guide
Electrical
Input
Tolerances
Temperature
Humidity
Altitude
The work area noise generated by the library amounts to 57.4 dB(A).
1
Die arbeitsplatzbezogene Geräuschemission des Gerätes beträgt
Deutch:
57.dB(A).
LVD SCSI configurations have a maximum allowable bus length of 12
meters (39 feet). To determine the cable length of the bus, measure the
lengths of the SCSI cables connecting each device to that bus and add
those lengths together. To that total length, add 12.25 inches (31.10 cm)
for the internal SCSI cable length of each SCSI tape drive.
90-264 VAC, 47-63 Hz
Voltage
300W (average)
Power
Temperature
(Operating)
+50°F to 95°F
(+10°C to +35°C)
20% to 80%
non-condensing
-500 to +10,000 feet
(-152 to +3,048 meters)
Appendix A Specifications
Environmental Specifications
Scalar 50
Temperature
(Non-Operating)
-40°F to +149°F
(-40°C to +65°C)
10% to 90%
non-condensing
-500 to +40,000 feet
(-152 to +12,192 meters)
181

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents