Quantum Scalar 50 Quick Start Manual

Tape library
Hide thumbs Also See for Scalar 50:

Advertisement

Quick Start Guide

Introduction

The Scalar 50 tape library is an automated storage and retrieval device
consisting of up to two full height tape drives or four half height tape drives
and up to 32 SDLT cartridges or 38 LTO tape cartridges (see
This instruction uses the following conventions:
Note:
Notes emphasize important information related to the main
topic.
Cautions indicate potential hazards to equipment and are
Caution:
included to prevent damage to equipment.
Warning:
Warnings indicate potential hazards to personal safety and
are included to prevent injury.
This document explains how to unpack the Scalar 50 tape library and install
it in a standard 19 in. rack. Once the library is unpacked and installed, set
up the library using the instructions in the Scalar 50 User's Guide PN 81-
81768. This installation procedure will take approximately 4 hours to
complete.
It is recommended to review the entire document prior to
Note:
beginning the installation.
Scalar 50
figure
1).
Scalar 50 Tape Library
Contents
Introduction..............................................1
Choosing a Location.................................2
Rack Space Requirements .....................2
Environmental Conditions ....................2
Providing Necessary Tools ....................3
Taking ESD Precautions .........................3
Installing the Library................................6
Installing the Library.............................7
Initial Configuration............................23
Setup Wizard ..........................................31
Multiple Library Stacks ..........................36
0

Advertisement

Table of Contents
loading

Summary of Contents for Quantum Scalar 50

  • Page 1: Table Of Contents

    This document explains how to unpack the Scalar 50 tape library and install it in a standard 19 in. rack. Once the library is unpacked and installed, set up the library using the instructions in the Scalar 50 User’s Guide PN 81- 81768. This installation procedure will take approximately 4 hours to complete.
  • Page 2: Choosing A Location

    Scalar 50 Quick Start Guide Figure 1 Scalar 50 Tape Library Choosing a Location When choosing an installation site for the Scalar 50, consider the following requirements: • • Table 1 Rack Space Requirements Dimensions Table 1 Rack Requirements Depth...
  • Page 3: Preparing For The Installation

    These environmental conditions apply when the Scalar 50 tape library is in operation. Note: Preparing for the Installation Before you begin the installation procedure in this section, make the following preparations as described in this section: • • Providing Necessary...
  • Page 4: Unpacking The Scalar 50 Tape Library

    Scalar 50 Quick Start Guide Unpacking the Scalar 50 Tape Library This section explains how to unpack the Scalar 50 tape library and move it to its final installation location. Note: By following these instructions, you help ensure that the system will continue to be safeguarded after it arrives at the installation site.
  • Page 5 Fold the sheet down. With the help of a second person, lift the library up off of the antistatic sheet. Place the library Scalar 50 the table or desk next to the antistatic sheet. If this is a multiple library stack, see proceeding.
  • Page 6: Installing The Library

    • • Locating the Mounting The Scalar 50 tape library is designed to fit in a standard 19 inch wide rack. Position It is important to the library installation to locate the hole pattern in the rack rails and install clip nuts if required (see the hole pattern to ensure that the library does not interfere with other devices in the rack.
  • Page 7: Installing The Library

    Front panel screws mounting positions If the rack is empty at the time of installation, do NOT install the Scalar 50 tape library too high in the rack. The weight of the library may cause the rack to become “top heavy” and unstable if installed in the top of an empty rack.
  • Page 8 Scalar 50 Quick Start Guide Table 3 Library Mounting Hardware 4 metric and 4 standard 4 sets 2 sets 2 sets Installing the Rack Mount Shelves Before installing the rack mount shelves, you must collect the following information: • •...
  • Page 9 Use these holes for rack depths of 27 in (68.5 cm) to 36 in (91.4 cm) Installing the Library Scalar 50 Tape Library figure Use these holes for rack depths of 27 in (68.5 cm) to 36 in (91.4 cm)
  • Page 10 Scalar 50 Quick Start Guide The metal fold Figure 5 Assembling the Left must be toward and Right Rack Mount Shelves the outside of the self as shown M5 x 10 Allen screws Loosely attach the rack mount shelves to the extenders with 4 M5 x 10 Allen...
  • Page 11 (opposite blocks) on rails with non-threaded circle hole patterns Use the rail adapters with small circle pegs on rails with threaded circle hole patterns (M6 on one side and M5 on the other side) Installing the Library Scalar 50 Tape Library...
  • Page 12 Scalar 50 Quick Start Guide Figure 7 Assembling the Left- Hand Rack Mount Shelf Rail adapter M5 x 10 Allen screws Attach the appropriate rail adapter to the front and back of the rack mount shelves (right and left) with 2 M5 x 10 Allen screws per adapter (see...
  • Page 13 Mounting plate • 2 M4 x 12 Allen screws. The rack mount shelves must be installed on the inside rack rails. Note: Mounting plate M4 x 12 Allen screws Left shelf Right shelf Installing the Library Scalar 50 Tape Library...
  • Page 14 Scalar 50 Quick Start Guide 3 Once the rack mount shelves are secured to the rack, tighten the Allen screws Figure 9 Tightening the Rack Mount Shelves securing the adjustable shelves (right and left) together (see Tighten screws to secure...
  • Page 15 32 to 33 in. 33 to 34 in. The Scalar 50 tape library weighs approximately 52 lbs (23.6 kg). At least two people are required to lift and install the library. position is easily determined. The mounting positions differ depending on the depth...
  • Page 16 Scalar 50 Quick Start Guide Back mounting clamp Rack Depth 34.5 to 35.5 in. 35.5 to 36.5 in. Figure 10 Installing the Back Mounting Brackets #1 Holes #2 Holes Back Mounting Bracket (Mounting Position) Use holes F and H Use holes G and I...
  • Page 17 Phillips screws. Warning: The Scalar 50 tape library weighs approximately 52 lbs (23.6 kg). At least two people are required to lift and install the library. Installing the Library Scalar 50 Tape Library...
  • Page 18 Scalar 50 Quick Start Guide Figure 12 Installing the Scalar 50 in the Rack Phillips screws 4 Secure the back of the library to the rack with two mounting clamps (see 5 Secure the mounting clamps to the rack rails with two Phillips screws on each side...
  • Page 19 Remove the tape drive cover plates (if necessary, some libraries ship with one tape drive installed) by loosening the captive screws securing the plate to the library chassis (see figure 14). Tape drive bay 2 Installing the Library Scalar 50 Tape Library Rail Tape drive bay 1 Cover plate...
  • Page 20 1 Connect the following cables and jumpers included in the accessory kit as shown in Insert the tape drive(s) into the drive bay(s) slowly until the connectors are seated. figure 15 for drive bay numbering (see the Quantum Scalar 50 Series Tape Drive Installation Instructions PN 81-81769 for information). Tape drive 2 Tighten the tape drive thumbscrews using a flat blade screwdriver.
  • Page 21 Figure 16 Scalar 50 Cable Configuration (SCSI Full Height Drives) Ethernet Figure 17 Scalar 50 Cable Configuration (Native Fibre Channel Full Height Drives) LTO Tape drives shown. SDLT drives have a single FC port Caution: The SCSI cables used to connect to the library system controller board MUST have an offset connector.
  • Page 22 Scalar 50 Quick Start Guide Figure 18 Scalar 50 Cable Configuration (SCSI Half- Height Drives) Figure 19 Scalar 50 Cable Configuration (SAS Half-Height Drives) Figure 20 Scalar 50 Cable Configuration (Native Fibre Channel Half-Height Drives) Ethernet SCSI host SCSI System Controller Board...
  • Page 23: Initial Configuration

    Figure 21 Scalar 50 Cable Configuration (Stacked) Host computer Host computer Ethernet The library host and Ethernet network are connected only to the Master library. 2 Connect one end of an AC power cable to each installed power supply and to a wall...
  • Page 24 Scalar 50 Quick Start Guide Turning on the Library To turn on the library: 1 Verify that: 2 Turn on the library by pushing power button located on the bottom left-hand corner Figure 22 Turning on the Library • Power cables are firmly in place •...
  • Page 25 Avoid touching the printed circuit board. Caution: When removing the hand restraint, ensure that the robotics umbilical cable is lying down in the correct position inside the platform and not across the robotics track. Installing the Library Scalar 50 Tape Library...
  • Page 26 Scalar 50 Quick Start Guide Figure 23 Removing the Hand Restraint Hand restraint installed Thumb screws Hand restraint Robotics umbilical cable Thumb screws Installing the Library...
  • Page 27 Save the hand restraint for later shipping or relocation of the library. Install the tape cartridge magazines. Note: Refer to the Scalar 50 User’s Guide (PN 81-81768) for more information on loading the tape cartridge magazines. Close the front doors.
  • Page 28 Be sure to check for the restraining bolt on the left side of the cabinet (see the Scalar 50 User’s Guide PN 81-81768 located on the documentation CD for more information).
  • Page 29 Capacity Key role(s) accordingly to create the multiple library stack. Note: If you are configuring a multiple library stack, the Scalar 50 in the bottom most position in the stack MUST be the Master library. press Enter. The Date and Time screen displays (see...
  • Page 30 Scalar 50 Quick Start Guide Figure 27 Date and Time Screen 2 Use the up and down arrows to view or edit the time zone, date, and time 3 When you are finished viewing/editing the date and time information, press Exit to...
  • Page 31: Setup Wizard

    (see The library shuts down. The Scalar 50 tape library is initially configured. To complete the installation, continue with Setup Wizard.
  • Page 32 Scalar 50 Quick Start Guide Figure 29 Overview Page 4 To access the Figure 30 Setup Wizard 5 Click , from the Setup Wizard top of the page. displays (see figure Setup Wizard to continue. Next page displays (see Setup Wizard (Library Offline)
  • Page 33 (see Setup Wizard (Date and Time) down boxes for the system time. to continue. Next Setup Wizard (Configure Devices) Setup Wizard Scalar 50 Tape Library figure 32). button for the system date and drop Change page displays (see figure...
  • Page 34 Scalar 50 Quick Start Guide Figure 33 Setup Wizard (Configure Devices) 9 Set the SCSI ID for the SCSI devices in the library. 10 Click Figure 34 Setup Wizard (Configuring Load Ports) 11 Enable or disable the load ports for this library.
  • Page 35 Enable/disable Auto Clean for this partition. to continue. Next Setup Wizard (Wizard Completed) to return to the page. Exit Status to reboot the library. Utilities page displays. Utilities Reboot Setup Wizard Scalar 50 Tape Library page displays (see figure 36).
  • Page 36: Multiple Library Stacks

    • Preparing the Library for a If the library will be installed in a rack with other Scalar 50 or PX502 libraries, you must Multiple Library Stack prepare each chassis prior to installation. Preparing the library chassis for installation into a multiple library stack consists of: •...
  • Page 37 Install only the bottom alignment hardware on the top library in the stack and the top alignment hardware on the bottom library in the stack. Multiple Library Stacks Scalar 50 Tape Library Remove only the top FlexLink cover on the...
  • Page 38 Scalar 50 Quick Start Guide Screws Figure 38 Installing the Alignment Hardware Top alignment hardware Bottom alignment hardware Screws The libraries are prepared for installation in a multiple stack. Multiple Library Stacks...
  • Page 39: Testing The Library Configuration

    IP address is the IP address for the Address Quantum Scalar 50. Note: The default username and password is page displays (see figure Overview tab. Utilities page displays (see figure Utilities Testing the Library Configuration Scalar 50 Tape Library admin 39): Utilities tab 40).
  • Page 40 Scalar 50 Quick Start Guide Figure 40 Utilities Page System Tests 5 The library must be offline prior to running a health check. Click 6 Click the Figure 41 System Test Page Cabinet Selection The library goes offline. tab at the top of the page.
  • Page 41 The system performs a health test on all robotic axis. The test results can be viewed at the bottom of the page. If any failures occur, contact Quantum. The following procedure requires at least one tape cartridge in the bottom most library in the library stack.
  • Page 42: Enabling Capacity On Demand

    3 Turn the system Enabling Capacity on Demand If you have purchased a Quantum Scalar 50 with full slot capacity, you must complete the following procedure to enable full slot capacity. 1 Retrieve and record the Scalar 50 Library serial number.

Table of Contents