To view the scale's capacity, software version and to print current setup information, follow this proce-
dure:
1. Press the — key. Then enter 7777.
2. Press the setup/cal key. The scale will display "rEF n.n", where "n.n" is the software version
number. At the same time the scale will transmit all current setups via RS-232 to a printer,
computer or other external device.
3. Press the clear key. The scale will display "nnn g", where nnn is the capacity of the scale in
grams.
4. Press the clear key to return the scale to normal operation.

RESTORING THE FACTORY DEFAULT SETUPS

The many features described in this section allow the user to customize the Setra Super Count to suit
a particular application. However, in doing this, it is also possible to inadvertently setup the scale in
such a way that it will not operate as expected. To reset the scale to the original factory defaults follow
the steps outlined below.
The factory defaults are set as follows:
-
Baud Rate equal to 2400 and no parity.
-
print is assigned to a standard serial tape printer to Dymo Setra 300 label format with
all available data being printed.
-
alt print is assigned to the Setra Auto Count 200 bar code label printer.
-
No minimum sample size.
-
The minimum accuracy is 95%.
-
The display hysteresis is enabled.
-
The int mode is set to fast update.
-
All weighing units enabled.
-
Database disabled.
To restore the factory default set-ups use the following procedure:
1. Press the — key.
2. Enter 8888.
3. Press the setup/cal key. The display will read "dEFALt".
4. Press the setup/cal key to restore the factory defaults. Press clear if you do not wish to pro-
ceed.
WARNING:
Restoring the factory default setups will erase any span calibration and return
the Super Count to the factory calibration.