Setra Scale Data
ID 0
ID 1
ID 2
ID 3
ID 4
ID 5
ID 6
ID 7
Gross
Net
Tare
A.P.W.
A.P.W. exp.
Count
Acc Count
Acc Ct Ents
Acc Weight
Acc wt Ents
Units word
Units ltr.
Setra codes
Units jump code
X of "x or y seq."
Y of "x or y seq."
Time
Date
Pause(.1)
62
128
transmit ID field 0 "S" id
129
transmit ID field 1 "D" id
130
transmit ID field 2 "R" id
131
transmit ID field 3 "L" id
132
transmit ID field 4 "N" id
133
transmit ID field 5 "Y" id
134
transmit ID field 6 "H" id time, if installed
135
transmit ID field 7 "B" id
138
transmit gross weight in external resolution
139
transmit net weight in external resolution
140
transmit tare weight in external resolution
141
transmit APW in internal resolution
142
transmit APW in exponential notation
143
transmit count
144
transmit count accumulator value
145
transmit count accumulator entries
146
transmit weight accumulator
147
transmit weight accumulator entries
148
transmit units label, e.g., "grams", "pounds"
149
transmit units letter, e.g., "g", "p"
150
ignored in scale, interpreted during setup to insert
the appropriate scale control codes.
151
transmit units code number and J, e.g., "1J", "3J"
152
transmits the X of the "X of Y" sequence.
153
transmits the Y of the "X of Y" sequence.
154
transmit the time hh:mm AM, from the Super Count
with time/date option.
155
transmit the date mm/dd/yy, from the Super Count
with time/date option.
156
Pause for a specified time before continuing to
transmit the script.
(Argument code 1 to 99, e.g. 5 = .5 second pause,
25 = 2.5 second pause.)
TM
Setra Super Count
Operator's Manual
Need help?