CLEARING THE ACCUMULATED COUNT OR WEIGHT
The count and weight accumulators are stored in non-volatile memory. They will be retained when the
scale is powered down. Follow the appropriate procedure below to clear the accumulator registers.
To clear an ID count accumulator:
1. Enter the ID, up to ten characters.
2. Press the id key.
3. Enter the count mode by entering an APW or sampling.
4. Enter 0 and press accum. Both the count accumulator and ID count accumulator will be set to
zero.
To clear an ID weight accumulator:
1. Enter the ID, up to ten characters.
2. Press the id key.
3. Press clear if the scale is not displaying the weight.
4. Enter 0 and press accum. The scale will set both the weight accumulator and ID weight accu-
mulator to zero.
To clear all ID count and weight accumulators:
1. Press the setup/cal key, enter 0 and press accum. The scale will set all accumulators to zero.
EXAMPLES OF ACCUMULATING COUNT BY ID
A manufacturer wants to accumulate the number (count) of widgets produced by several operators.
Each operator will produce approximately 100 widgets before delivering them to a stocking location.
At the stocking location, an inspector will count the widgets by sampling them on the scale. In addi-
tion, the inspector wants to record how many widgets were produced by the operator, the operator's
ID number, the time of day and the total number of widgets produced so far that day.
RESETTING COUNT AND WEIGHT ACCUMULATOR REGISTERS
The inspector wants to count the widgets produced during the shift; therefore, the ID count accumu-
lators should be cleared at the beginning of each shift.
1. Enter the count mode by entering an APW or sampling.
2. Press setup/cal, enter 0 and press accum. The scale will set the count and weight accumula-
tors and all ID count and weight accumulators to zero.