9. Wait for the "OK" symbol, then read the display. The scale now reads the total number of
pieces on the pan.
10. Add pieces until you reach the desired count.
11. Wait for the "OK" symbol, then read the display.
COUNTING WITH A CONTAINER
You can use a container when counting pieces without including the container weight in the count.
Your scale can do this by "taring out" (subtracting) the weight of the container before it begins count-
ing. If you wish to retain the container weight for later reference, the tare key should be used in step
#3 below. If you do not need to retain the container weight, and do not need to display or print the
gross weight, use the zero key only. To tare out or zero out the weight of a container, use the following
procedure:
1. Press the zero key.
2. Place the container on the pan.
3. Press the tare key or zero key. (If the tare weight is known, a full container may be placed on
the pan in step #2. In this case, enter the tare weight through the keyboard and then press the
tare key.)
4. Wait for the "OK" symbol, then press the sample size key.
5. The scale display will say "Add 10. PC". (The sample size requirement can be increased by
pressing the sample size key repeatedly. The predetermined sample sizes are: 10, 25, 50 and
100 pcs. This sequence of predetermined sample sizes will repeat itself as the sample size
key is pressed.)
6. When you reach the desired sample size, place the requested number of pieces in the con-
tainer.
7. Press the count key.
8. Wait for the "OK" symbol, then add pieces until you reach the desired count.
9. Wait for the "OK" symbol, then read the display. The scale will read the total number of pieces
you have placed in the container.
NOTE: You may recall the tare weight by pressing display, tare, but only if it was stored in step #3 by
using the tare key and not the zero key.
DISPLAYING THE GROSS WEIGHT DURING COUNTING
To display the gross weight during a counting procedure, perform the steps below:
1. Press the gross key to display the gross weight.
2. Press count to return to the counting mode.
The gross weight will equal the net weight unless a container weight has been entered using
the tare key (see section, Counting with a Container above).