CONTINUOUS PRINT MODE
The Super Count's continuous print feature allows you to program the scale to print at specified time
intervals. For example, to print every five seconds you would enter 5 and press the print key. Since
the key sequence is the same for initiating a script to print, the factory default for this setup is dis-
abled.
To change the continuous print mode follow the steps below:
1. Enter —22220 and press the setup/cal key. The scale will display "IntPrt".
2. To Enable the Continuous Print Mode
Press the setup/cal key. The scale will return to the normal weighing mode.
To Disable the Continuous Print Mode
Press the clear key. The scale will display "no Int". Press the setup/cal key to disable the
continuous print mode. The scale will return to the normal weighing mode.
To Exit This Procedure
Press the clear key to exit from this procedure without changing the status of the continuous
print mode.
If the continuous print mode is enabled, the number that corresponds to the selected time interval
cannot be used as a script's identifying number. For example, if you wanted to print every 7 seconds,
the number 7 could not be used as an identifying number to store a script.